Standard Operating Values
Trigger Tubes 1.10 1.15 1.20
high hihi maxc
    Home Current (uA)     Home Current (uA) P1 2424 2535 2645
  HV (V) no beam beam   HV (V) no beam beam A1 2210 2310 2411
Spare DISABLED     SPARE1 DISABLED     DI 1177 1231 1284
P1 -1850   2204 P2 -1750   2079 P2 2287 2391 2495
A1 -1700   2009 A2 -1750   2089 A2 2298 2402 2507
DI -1800   1070         VetoN 2724 2847 2971
VetoS 2917 3050 3182
Veto Tubes
D1I 2373 2481 2588
    Home Current (uA)     Home Current (uA) D2I 2366 2474 2581
  HV (V) no beam beam   HV (V) no beam beam A1U 2380 2489 2597
VetoN -1800   2476 VetoS -1800   2652 A1D 2384 2492 2600
A2U 2362 2469 2576
MAPMT Tubes A2D 2379 2487 2596
A1I 2396 2505 2614
    Home Current (uA) Position (mm)     Home Current (uA) Position (mm) A1O 2369 2477 2585
  HV (V) no beam beam nominal max   HV (V) no beam beam nominal max A2I 2402 2512 2621
D1I -940 2138 2157   33.60 D2I -940 2131 2151   30.69 A2O 2407 2516 2626
                       
A1U -940 2135 2164   30.60 A2U -940 2133 2147   33.35 P1U 2373 2481 2588
A1D -940 2134 2167   35.11 A2D -940 2138 2163   35.44 P1D 2372 2479 2587
                       
A1I -940 2158 2178   18.48 A2I -940 2152 2184   20.91 P2U 2375 2483 2591
A1O -940 2142 2154   23.42 A2O -940 2145 2188   27.98 P2D 2373 2481 2588
                       
P1U -940 2135 2157   28.08 P2U -940 2135 2159   30.07 P1I 2408 2517 2627
P1D -940 2133 2156   25.96 P2D -940 2133 2157   27.43 P1O 2401 2510 2620
                       
P1I -940 2171 2189   30.57 P2I -940 2156 2187   32.52 P2I 2406 2515 2624
P1O -940 2157 2183   28.41 P2O -940 2159 2184   33.69 P2O 2402 2512 2621
If a voltage box is green, ramp that voltage. Disabled slots are because there are no tubes attached to that channel.
Values in this table are set as 100% in the HVGui.
If a name is orange, that channel goes to PAUSED state when ramping to 0. Ack the minor error this causes.
If a positon box is green, try to insert that pot. If red, it is disabled.
Currents are for reference and to check if tubes are working properly. Beam values will vary store by store.
Max position is for reference and is the value where halo was effected by 1.25% or rates exceeded 300kHz
Use the provided insertion tables to determine operating positions for pots. It is not uncommon for quadrupole pots to have their
rates double over the home rate. Dipole pots will have end rates as much as 6 times higher. If a pot has rates over 250kHz
at home, it is unlikely that it can be successfully inserted. End points are determined by rates above 250kHz or an
increase in appropriate halo of 20% phalo < 10kHz, 20% ahalo < 6kHz, whichever occurs first. You can exceed the 250kHz if you 
are close  to nominal and the rate will not exceed 300kHz by much.
Depending on home rates, try the closest insertion table possible (one with smallest sigma). Look over old elogbook entries
to see where pots have been inserted recently for comparison.