Calibration Run Steps ----- // 1 \\ ------- CALIBRATION - Take out 50, 52 and 13 from global run - Disable CFT board - Global Parameter (come back to CFT GUI main) - * Set -> SVX to "use global th" * Set -> SDAQ > nsteps_v_thres 0x0 > nsteps_v_ref 0x86 > v_ref 0x78 > n_events_sift_hits 0x0 > run event 100 - Download ----- // 2 \\ ------- TAKING DATA - locate o create PPC in crate 52 - start Taker or use the one already opened - check DAQ monitor (~95%) - write run number down ----- // 3 \\ ------- TRANSFERING DATA - for each crate > hit new vref > hit new svxth - plot ThresVrefVthres - plot vref change - plot svxThres change ----- // 4 \\ ------- LOOKING DATA - d0ol24 - run cft_sdaq ----- // 5 \\ ------- ENDING ACTIONS - re enable VRBs - plot > thres > vref change > svx change - deselect "use global th" - download crate 52